27 Oct Future-Proof Your Building with Smart Smoke Containment Solutions

Smoke Containment System Singapore: Advanced Protection for Modern Buildings
When a fire breaks out, controlling smoke movement is just as critical as suppressing the flames. While smoke ventilation removes smoke and evacuation systems clear escape routes, smoke containment systems play a different, but equally vital role: keeping smoke confined to its origin zone.
In Singapore, where buildings are tall, complex, and densely populated, smoke containment systems have become a core requirement in modern fire safety design. These systems are essential for maintaining tenable conditions, protecting critical pathways, and ensuring compliance with SCDF (Singapore Civil Defence Force) fire safety standards.
What Is a Smoke Containment System?
A smoke containment system is an engineered fire safety solution designed to control and restrict smoke migration between compartments in a building during a fire.
Unlike ventilation or extraction systems, its main objective is:
Preventing smoke from spreading to unaffected zones
Preserving safe egress routes for occupants
Improving operational conditions for firefighters
Maintaining compartmentation integrity during emergencies
In practical terms, it contains the smoke at its source while other systems (ventilation, suppression, evacuation) manage removal and occupant safety.
How Smoke Containment Systems Work
Smoke containment relies on a combination of physical barriers, airflow control, and pressurization. Here’s a simplified sequence:
Step 1: Fire Detection and System Activation
- Automatic fire detectors or sprinkler flow switches identify the fire zone.
- Control systems trigger smoke barriers and door controls.
Step 2: Compartmentalization
- Smoke curtains, fire doors, and automatic dampers close to seal off the affected zone.
- This forms a smoke “envelope” that prevents lateral movement.
Step 3: Pressure Differentials
- Escape routes (e.g., stairwells, lobbies, lift shafts) are positively pressurized, pushing smoke back into the fire zone.
- This ensures that doors can be opened easily while smoke remains contained.
Step 4: Coordinated Ventilation and Extraction
- Mechanical extraction fans remove smoke from the contained zone.
- Fresh air is supplied to maintain stable pressure levels.
Step 5: Manual Override and Firefighter Control
Firefighters can override the system via control panels to adjust pressure, open barriers, or direct smoke movement as needed.
Key Components of a Smoke Containment System
An effective containment system involves multiple integrated components:
| Component | Function |
| Smoke curtains & fire curtains | Create temporary compartmentation to block smoke spread |
| Fire-rated doors & dampers | Automatically close during activation to seal fire zones |
| Pressurization fans | Maintain pressure in escape paths |
| Control panels & sensors | Coordinate response with other fire protection systems |
| Air inlet & exhaust ducts | Manage airflow and pressure balance |
| Seals, glazing, shaft enclosures | Prevent leakage and uncontrolled smoke migration |
These components are typically linked to fire alarm systems, Building Management Systems (BMS), and ventilation networks.
Importance of Smoke Containment in Singapore
Singapore’s high-density urban environment presents unique challenges:
- High-rise buildings increase vertical smoke migration risk
- Mixed-use developments require multi-zone fire strategies
- Underground facilities (e.g., MRT stations, carparks) have limited natural ventilation
Why containment matters:
Keeps escape routes clear for longer durations
Allows safe access for rescue and firefighting
Prevents smoke contamination in adjacent compartments
Protects critical assets and operations (e.g., data centers, hospitals)
Fulfills Fire Code requirements under SS 553 and SCDF regulations
Regulatory & Compliance Considerations
In Singapore, smoke containment systems must comply with:
- Singapore Fire Code (latest revision)
- SS 553: Code of Practice for Air-Conditioning and Mechanical Ventilation
- SS 598: Fire Safety Requirements for Smoke Curtains
- SCDF Fire Safety Guidelines
Key compliance factors:
✅ Smoke curtain performance (temperature resistance, leakage rating)
✅ Pressurization levels for stairwells and lobbies (≥ 50 Pa)
✅ Integration with alarm and control systems
✅ Emergency power supply redundancy
✅ Annual testing and maintenance certification
Failure to comply can result in enforcement actions, delays in Temporary Occupation Permits (TOP), and increased liability.
Applications of Smoke Containment Systems
| Sector | Common Application | Containment Method |
| Commercial Buildings | Protecting lift lobbies and corridors | Pressurization + curtains |
| Hospitals | Protecting vulnerable occupants | Compartmentalization & dampers |
| Transportation Hubs | MRT stations, airports | High-performance curtains & exhaust |
| Data Centers | Asset protection | Sealed zones & pressurization |
| Malls & Atriums | Controlling open space spread | Zoning with smoke curtains |
Each use case requires custom engineering based on airflow modelling, fire load, and evacuation time calculations.
Engineering & Design Best Practices
When designing a smoke containment system, M&E consultants and building owners should consider:
Building geometry and fire zones — proper compartmentation strategy
Air leakage control — minimize bypass paths
Integration with smoke control and evacuation — holistic system response
Accessibility for maintenance — easy inspection of barriers and fans
Redundancy and fail-safe design — ensure performance even during power failure
Testing and commissioning — pre-occupancy verification
Tip: Early integration during building design saves costs and improves compliance outcomes.
Advancements in Smoke Containment Technology
Modern containment systems are moving beyond simple barriers. Trends include:
Automated adaptive control systems with real-time smoke modelling
BMS integration for centralized monitoring
Modular smoke curtains that deploy selectively
IoT-enabled sensors for dynamic pressure management
Hybrid containment + ventilation strategies for complex buildings
This aligns with Singapore’s Smart Nation initiative and growing demand for energy-efficient fire safety systems.
Maintenance and Testing Requirements
To remain reliable during a fire, smoke containment systems require regular inspection and testing:
- Quarterly function tests for fans, curtains, and dampers
- Annual full-system performance testing
- Seal integrity checks to prevent smoke leakage
- Control system and power supply validation
- Documentation for SCDF inspection and audits
A well-maintained system ensures swift and predictable performance, reducing casualties and property loss.
Frequently Asked Questions (FAQ)
How is smoke containment different from smoke ventilation?
Containment prevents spread of smoke, while ventilation removes smoke from affected areas.
Is smoke containment mandatory in Singapore?
Yes, for many building types such as high-rise, MRT stations, and atriums, in accordance with Fire Code and SCDF guidelines.
What types of buildings benefit most?
Hospitals, commercial towers, transport hubs, data centers, and malls often require containment strategies.
How often should containment systems be tested?
Functional testing is typically required quarterly, with annual full commissioning.
Can containment be retrofitted in existing buildings?
Yes. Modular systems allow retrofitting without major structural changes.
Conclusion: Containment is the First Line of Defense
In a fire, controlling where smoke can and cannot go is a life-saving strategy. Smoke containment systems play a critical role in ensuring safe evacuation, effective firefighting, and legal compliance in Singapore’s complex built environment.
Whether you’re developing a new building or upgrading an existing one, integrating a robust smoke containment strategy ensures that your fire protection system isn’t just reactive, it’s proactive.